2 t steam capacity per hour boiler

A water tube boiler has a capacity of 1000 kghr of steam

379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. And the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.

Learn More

Steam Pipe Sizing: Steam and Steam Heat Exchanger Basics

When selecting steam pipe sizes, the engineer or contractor is asked to fill in the capacity, the steam pressure, and the velocity required. The answer is a pipe size and a pressure drop per 100 feet of pipe. Let's look at this required data. The capacity is simply the maximum flow rate in pounds per hour or PPH. Steam Pressure and Pipe Sizing

Learn More

Boiler Capacity - Engineering ToolBox

Lbs Steam delivered per Hour. Large boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions. BTU - British Thermal Units. Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British

Learn More

how can calculate how much steam is to be required for

how can calculate how much steam is to be required for generation of 1MW electricty?.. Answer / tejeswararao That is depend up on turbine design if it is seimens turbine 3.8 tons more than enough if it is triveni turbine it may 4.5tons like that and it may vary as per load curve

Learn More

Can anyone explain to me Cycle Rate Per Hour that

Can anyone explain to me Cycle Rate Per Hour that Honeywell uses in their thermostats. I understand how an adjustable swing temp works and determines how often the cooling and heating system operates-depending on whether the swing in 1/2 degree or 1 degree or more from the set point, but how does changing the Cph in Honeywell thermostats change anything.

Learn More

Direct Steam Kettles Sizing Charts & Formulas

The following formulas provide the information needed to convert between the various parameters used to measure steam power or heat transfer capability over a period of time (typically, one hour). 1 Boiler Horsepower = 35.2 lb. of steam/hr. 1 Boiler Horsepower = 34,130 BTU/hr. 1 Boiler Horsepower = 9,993 Watts/hr.

Learn More

Boiler Formulas - Debco Equipment

Boiler Formulas: Common Conversion Factors. Boiler HP x 34.5 Boiler HP x.069 Boiler HP x 33.4 Boiler HP x 139 BTU/Hour Output ч 240 EDR/1000 x 0.5 Lbs of Steam /Hr ч 500 = Lbs. of Steam per Hour = Evaporation Rate Gallons per Minute (GPM) = MBTU per Hour Output (MBH) = Sq. Feet of Equivalent Direct Radiation (EDR) = Sq. Feet of Equivalent

Learn More

PDF Characterization of the U.S. Industrial/Commercial Boiler

this energy is used in boilers to generate steam and hot water. EEA estimates that there are almost 163,000 industrial and commercial boilers in the U.S. with a total fuel input capacity of 2.7 million MMBtu/hr. These boilers consume about 8,100 TBtu per year, accounting for about 40 percent of all energy consumed in these sectors. This report

Learn More

Instant Steam Boiler | Capacities 500 kg/h to 2,000 kg/h

The CERTUSS Universal TC Model Generator offers a 2 stage burner operation, with full modulation feature (50 % to 100 %) in second stage burner position. With the CERTUSS Universal TC Model generator steam is produced in under 5 minutes and it can cope with both a constant or fluctuating steam demand.

Learn More

PDF Heat Engines vol 2

1.2 Elements of a Steam Condensing Plant The main elements of a steam condensing plant are : — a condenser in which the exhaust steam in condensed, — supply of cooling or injection water, for condensing exhaust steam, — a pump to circulate the cooling water in case of a surface condenser, — a pump, called the wet air pump, to remove the condensed steam (condensate), the air,

Learn More

1000 HP Trailer Mounted Rental Boiler - POWER MECHANICAL

Capacity: 1,000 BHP / 34,500 PPH / 34MM BTUs Water evaporation (steam): 70 GPM Water circulation (HW): 670 - 6,700 GPM Outputs: Low pressure steam, High pressure steam, Hot water, High Temp Hot Water (HTHW) Fuels: Natural Gas / LP: 42,000,000 BTUs (Max) #2 Oil: 299 GPH (Max) Voltage: 208-230V, 480V, 600V 3-phase/60Hz; Boiler brands: York-Shipley Global, Superior

Learn More

PDF Pipe Sizing Steam Supply andCondensateReturn Lines

1—5" gate valve at 2.2 = 2.2 ft Total for valve and fittings = 35.2 ft Adding this to the 50-foot length of pipe gives a total effective length of 85.2 feet —call it .85 hundred feet. Dividing our maximum allowable pressure drop of 1.0 by .85 gives 1.18 psi per 100 feet. Refer to Table 45-2 for 15 psig steam. With a

Learn More

Combustion of Number 2 Fuel Oil,

Average of 155,500 BTUs per gallon. Table 1- Approximate Gravity and Calorific Value of Standard Grades of Fuel Oil Commercial Standard No. Approximate Gravity (API) Weight Pounds per Gallon Heating Value Range BTU per Gallon Kerosene 50-42 6.00-6.49 135,550-131,100 1 30-45 6.95-6.67 137,000-132,900 2 30-45 7.21-6.87 141,000-135,800

Learn More

BOILERS | Energy-Models.com

Fire tube or "fire in tube" boilers; contain long steel tubes through which the hot gasses from a furnace pass and around which the water to be converted to steam circulates. (Refer Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5 kg/cm 2.

Learn More

Spirax Sarco FTB-125 Cast Iron Float & Thermostatic Trap

The Spirax-Sarco float and thermostatic (F&T) high capacity steam trap, model FTB-125, features a 2-1/2″ trap connection in a same side parallel configuration. This pattern allows steam to enter from one side of the trap, and the condensate to discharge from the same side of the trap.

Learn More

Hurst Boiler and Welding Inc. | Boilers | Biomass Boilers

Hurst Boiler & Welding Company, Inc. has been manufacturing, designing, engineering and servicing gas, oil, coal, solid waste, wood, biomass and hybrid fuel-fired steam and hot water boilers since 1967, for thousands of satisfied customers.In addition to a complete line of steam and hot water boilers, Hurst Boiler & Welding Company also manufactures a complete line of boiler parts and boiler

Learn More

PDF Steam Tables - Missouri

steam table. Total Heat of Steam (Column 6). The sum of the Heat of the Liquid (Column 4) and Latent Heat (Column 5) in Btu. It is the total heat in steam above 32°F. Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound. Specific Volume of Steam (Column 8). The volume per unit of mass in cubic feet per pound.

Learn More

Steam Trap Selection: Understanding Specifications | TLV

*Provided as a general reference. Please consult a steam specialist such as TLV if you are unsure about trap selection or piping design. Generally, the trap should never be sized smaller than the equipment outlet piping because this can lead to waterlogging and ensuing damage and / or heating problems.

Learn More

Steam Trap selection: How to calculate condensate loads

Approximate load can be considered as 30 Kg/ Hour for each 30 Meters of tracer line. Heating Water with Steam: Kg Condensate/ Hour = (LPH * Temperature rise in ºC )/500. Heating Fuel Oil with Steam Kg Condensate/ Hour = (LPH * Temperature rise in ºC)/1000. Heating Air with Steam: Kg Condensate/ Hour = (NM 3/ Min * Temperature rise in ºC)/27

Learn More

t/hour - Tonne Per Hour. Conversion Chart / Flow Rate by

This is a conversion chart for tonne per hour (Metric). To switch the unit simply find the one you want on the page and click it. You can also go to the universal conversion page. 2: Enter the value you want to convert (tonne per hour). Then click the Convert Me button. Your value gets instantly converted to all other units on the page. 3

Learn More

WOAH! Is that hot water boiler sized properly? | US Boiler

The customer said the old boiler heated the home "okay," so you decide to match the old boiler's size. Since the customer asked for an Alpine high efficiency condensing gas boiler, you review the product data sheet and discover that the closest Alpine models are 105,000 and 150,000 BTU/hr.

Learn More

How to Calculate the Amount of Condensate Per Amount of Steam

For instance, steam can be assumed to be 350 psia (pounds per square inch absolute), which has a temperature of 432 degrees Fahrenheit. This steam has a corresponding latent heat of 794 btu/lb. If the steam flow is 1,000 pounds per hour, then the total heat input per hour is 794,000 btu.

Learn More

Calculate How Much Steam to Heat Water - ProSonix

Contact the direct steam injection heating experts at ProSonix today to learn more about our process driven solutions & energy saving designs. Request More Info. Want to learn more about ProSonix products and services? Get in touch with us today to schedule a consultation. Contact Us.

Learn More

A manager of boiler drums wants to use regression analysis

Given the estimated regression equation, predict the number of worker-hours needed to erect a utility-field, steam-drum boiler with a capacity of 550,000 pounds per hour and a design pressure of 1400 pounds per square inch.

Learn More

Rental Boilers: Temporary Boiler Rental | Wabash Power

Whether you are working with a mobile boiler, a mobile steam plant, or a larger skid mounted boiler, you can expect the highest quality standards including: Largest and Newest Inventory. We have the largest and newest fleet of packaged rental boilers in the world. No boiler in our rental fleet is older than 2006 and most units are 2010 or newer.

Learn More

Subchapter 2. Boiler and Fired Pressure Vessel Safety Orders

(2) The largest single piece of fuel-fired equipment exceeds 1,000,000 B.t.u. per hour input capacity. Exception: Rooms housing high-pressure boilers (greater than 15 lbs. psi) where either of the conditions listed in (1) or (2) exist shall be provided with 2 exits. If two means of egress must be provided, one may be a fixed ladder.

Learn More

How to Calculate Boiler Steam Flows | Hunker

A boiler burning 20 gallons per hour would produce [(150,000 btu/gal x 20 gal/hr) / 970.28 btu/lb] x 0.85 (efficiency) for a total of 2,628.1 lb/hr of steam. Step 5 Calculate the combustion-air mass required to burn the 20 gallons of No. 6 fuel oil above.

Learn More

Useful Formulae | Coilmaster

Cooling/Heating: Total Capacity (BTU/hr) = 4.5 x CFM x (H ewb - H ₁wb) Sensible Capacity (Btu/hr) = 1.08 x CFM x (T 1 db - Tedb) Latent Capacity (Btu/hr) = 0.68 x CFM x (Grains H 2 O removed per lb. air) Sensible Heat Ratio = Sensible Heat / Total Heat. Lb per hr H 2 0 Removed = 4.5 x CFM x Grains H 2 0 removed per lb. air7000

Learn More

Hot Water Boiler - Min Relief Valve Capacity - Boiler and

Low pressure steam boilers (ASME Section IV) are generally designed for 15 psi steam/30 psi hot water. However the same size boiler can be designed for a higher pressure (hot water only) application by means of increased thicknesses of the parts making up the pressure vessel of the boiler, etc.

Learn More

Convert horsepower (boiler) [hp (boiler)] to ton

One horsepower is equivalent to 33,000 foot-pounds per minute, or the power required to lift 550 pounds by one foot in one second, and is equivalent to about 746 watts. Power also is measured in dBm, a relative logarithmic measure with 1 milliwatt as reference, calories per hour, Btu per hour (Btu/h).

Learn More

PDF A Scrap Tire- Fired Boiler - Columbia Engineering

scrap automobile tires per hour, generating 25,000 pounds (11 ,340 Kg) of process steam per hour. This paper discusses the fundamental design parameters, principles of cyclonic combustion, heat and material balance, air pollution control, and per· formance data of the scrap tire-fired boiler at Jack· son, Michigan. INTRODUCTION

Learn More

PDF T&P and ASME Safety Relief Valves - Watts

Selecting T&P Valves To select a T&P valve some basic applica - tion factors must be considered: sizing, location in the water heater and draining.

Learn More

steam boiler kapasitas 2ton merk miura | Gas Heater Boiler

We need know the details of10 bar 10 tons per hour horizontal boiler, for example capacity,steam boiler kapasitas 2ton merk miura - CFBC Boiler Post navigation newcrest mining bonikro recrutement de boiler an maker

Learn More

Sizing a Steam Boiler | U.S. Boiler Company

Next, compare this to the color brochure for the steam boiler and choose the boiler that meets the required load. An important note on boiler sizing - all the supply piping in the basement should be insulated with a minimum of 1" of pipe insulation. A better choice would be 1-1/2" or 2" of pipe insulation.

Learn More

How to size a condensate return unit - Xylem Applied Water

Rounding off, the boiler puts out half a gallon per minute of water in the form of steam per 1000 sq ft. EDR. When the steam cools and turns back to water, that's the condensate you have to deal with. Some common conversion factors: Multiply Boiler Horsepower (BHP) by 34.5 = Lb. of steam (water per hour (lb/hr) Multiply Boiler Horsepower (BHP

Learn More

PDF CONVERSION OF BOILER IN KG/H AND KW - cni.co.th

CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

Learn More

30 tons steam boiler of Longyuan Power Plant

Industrial Boiler Projects Liyang Longyuan Power Group Co., Ltd Model: SZS30-2.5-YQ Project Location: Puyang, China Installation Date: April 2017 Application: Power generation industry Capacity: Steam 30 ton per hour Rated Pressure: 2.5 Mpa Thermal Efficiency: >89% Heating Source: Biomass Fuel Liyang Longyuan Power Group Co., Ltd. was founded

Learn More

Your Go-To Guide for Steam Traps | Industrial Controls

Applying a 2.5 safety factor, an F & T trap rated at 15 Lb. with a capacity rating of 1000 Lbs./Hr. at 1 Lb. D P is our selection; a Sarco FT15 - 1 1/4". A cooling leg of at least 28" in height must be installed before the inlet of the trap, and the trap must drain to atmospheric pressure 0 psig.

Learn More

4 tons per hour Steam Capacity Boiler Used For Oil

4 tons of gas steam boiler - kuurnsezichten. 4 ton per/hour for natural gas steam boiler - zozen Steam Capacity: 1 ton 2 ton 3 ton 4 ton 5 ton 6 ton 8 ton 10ton to 20 tons per hour .2018 Gas Boiler Prices & Costs - Natural Gas, High Efficiency BoilersA gas boiler is similar to a gas furnace in that it is a system that uses natural gas -- like propane -- to heat

Learn More

How do you convert kcal into kg of steam - Answers

From steam tables. the enthalpy of liquid water at 20 °C is 20.05 kcal/kg and the enthalpy at 100 °C is 100.09 kcal/kg - for a change of 80.04 kcal/kg or 80 kcal for 1.0 kg of water (taking into

Learn More

Leave your email